10 VP-460 - The OSD Menu
5 The OSD Menu
The VP-460 OSD menu lets you set the operation parameters for the:
Main Window Control
PIP Window Control
Entire System Control
The nature of the operation setup appears in the OSD title, as shown in the
example in
Section 5.1
The title line shows the control mode (Main, PIP or Entire system)
:
Level 1 lists the main menu items
Level 2 includes the second hierarchy level, below level 1
Level 3 includes the third hierarchy level, below level 2
Function, is the selectable parameter or numerical value and can appear
either under level 2 or 3
5.1 OSD Menu Operation Example
In the example illustrated below, the Master Connection is set to SDI (see Section
5.7
The table below shows function 632 (from the Protocol in
).
Section 10.2.1
6 in the hundreds, represents “Scale” which is the 6
th
menu item in the main
menu list
):
3 in the tens, represents “Output” which is 3
rd
in the Scale menu
2 in the units, represents “Master Connection” which is second in the Output
menu
Level 1 Level 2 Level 3 Level 4 (Function) Range Function
Scale (6) Output (3) Master Connection
(2)
HDMI 0 632
SDI 1
Vedere la pagina 14