Kramer-electronics VP-790 Manuale Utente Pagina 10

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 18
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 9
8 VP-790 Blending Images - Setting Blend Width
Line 1 is the left hand edge of the right hand projection
Line 2 is the right hand edge of the left projection blend region
Line 3 is the left hand edge of the right projection’s blend region
Line 4 is the right hand edge of the left hand projection
Referring to
Figure 6 above, adjust line 3 to meet line 1 and adjust line 2 to meet
line 4. This adjusts the blend width of each projector so that the shadowed
alignment area is equal to the optical overlap.
Figure 7 shows a darker vertical strip on the right hand side where the blend width
has been adjusted past the overlap (blend width is too wide) and on the left hand
side a lighter vertical strip showing a blend width that is too narrow.
Figure 7: Blend Width Incorrectly Adjusted
Figure 8 shows the view when the blend widths on both Scalers are adjusted
correctly.
Vedere la pagina 9
1 2 ... 5 6 7 8 9 10 11 12 13 14 15 16 17 18

Commenti su questo manuale

Nessun commento