Kramer-electronics VP-790 Manuale Utente Pagina 121

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 126
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 120
VP-790 Protocol API Functions 117
2.113 121BUser
2.113.1 456BbyOsdCurrentUserSet
API index: 2947
Selectes the current user profile.
Input Parameters
Name Type Range Description
Value
UWORD32
0 .. 3
Profile number
Return Values
Name Type Range Description
Status
BYTE
0x00-0xFF
0 if successful, error code
otherwise
2.113.2 457BbyOsdCurrentUserGet
API index: 2948
Retrieves the currently selected profile number from either cache or the SPD.
Input Parameters
Name Type Range Description
Option BYTE 0: From cache
1: From SPD
Retrieval method
Return Values
Name Type Range Description
Status BYTE 0x00-0xFF 0 if successful, error code
otherwise
Value
UWORD32
0 .. 3
Profile number
2.113.3 458BbyOsdCurrentUserSave
API index: 2959
Saves the profile number from cache into the SPD.