Kramer-electronics VP-790 Manuale Utente Pagina 45

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 126
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 44
VP-790 Protocol API Functions 41
2.31 39BEdge Blend Bottom Border
2.31.1 225BbyOsdEdgeBlendBotBorderSet
API index: 3121
Sets the edge blend bottom border.
Input Parameters
Name Type Range Description
Value UWORD32 0x00-{output res./4} Sets the bottom border edge blend
size. The actual range depends on
Output resolution. It is limited to ¼ of
the output resolution.
Return Values
Name Type Range Description
Status BYTE 0x00-0xFF 0 if successful, error code otherwise
2.31.2 226BbyOsdEdgeBlendBotBorderGet
API index: 3122
Retrieves the edge blend bottom border.
Input Parameters
Name Type Range Description
Option BYTE 0: From cache
1: From SPD
Retrieval method
Return Values
Name Type Range Description
Status BYTE 0x00-0xFF 0 if successful, error code otherwise
Value UWORD32 0x00-{output res./4} Retrieves the top border edge blend
size. The actual range depends on
Output resolution.
2.31.3 227BbyOsdEdgeBlendBotBorderSave
API index: 3123
Saves the number from cache into the SPD.
Input Parameters
None
Return Values
Name Type Range Description
Status BYTE 0x00-0xFF 0 if successful, error code otherwise