122 VP-790 Protocol - API Functions
2.118 VT Filter Strength
2.118.1 byOsdVTStrengthSet
API index: 3240
Sets the strength of the vertical temporal filter.
Input Parameters
Name Type Range Description
Value UWORD32 0 .. 4 Strength of the VT filter. 0 means no
filtering and 4 being the highest
strength.
Return Values
Name Type Range Description
Status BYTE 0x00-0xFF 0 if successful, error code otherwise
2.118.2 byOsdVTStrengthGet
API index: 3241
Retrieves the strength setting of the vertical temporal filter.
Input Parameters
Name Type Range Description
Option BYTE 0: From cache
1: From SPD
Retrieval method
None
Return Values
Name Type Range Description
Status BYTE 0x00-0xFF 0 if successful, error code otherwise
Value UWORD32 0 .. 4 VT filter strength setting
2.118.3 byOsdVTStrengthSave
API index: 3242
Saves the strength setting of the vertical temporal filter from cache into the SPD.
Input Parameters
None
Return Values
Name Type Range Description
Status BYTE 0x00-0xFF 0 if successful, error code otherwise