Kramer-electronics VP-790 Manuale Utente Pagina 21

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 126
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 20
VP-790 Protocol API Functions 17
2.6 14B4-Corner Upper Right Corner
2.6.1 150Bby4CornerX2SetValue
API index: 782
Moves the x-position of the upper right corner. The value is stored in cash and
SPD, there is no separate Save function.
Input Parameters
Name Type Range Description
Value SWORD32 -1000 .. +1000 Moves the x-position of the upper
right corner.
Return Values
Name Type Range Description
Status BYTE 0x00-0xFF 0 if successful, error code otherwise
2.6.2 151BbyOsd4CornerX2Get
API index: 736
Retrieves the position.
Input Parameters
Name Type Range Description
Option BYTE 0: From cache
1: From SPD
Retrieval method
Return Values
Name Type Range Description
Status BYTE 0x00-0xFF 0 if successful, error code otherwise
Value SWORD32 -1000 .. +1000 Retrieves the position.
2.6.3 152Bby4CornerY2SetValue
API index: 783
Moves the y-position of the upper right corner. The value is stored in cash and
SPD, there is no separate Save function.
Input Parameters
Name Type Range Description
Value SWORD32 -1000 .. +1000 Moves the y-position of the upper
right corner.
Return Values
Name Type Range Description
Status BYTE 0x00-0xFF 0 if successful, error code otherwise
Vedere la pagina 20