VP-790 Protocol API Functions 75
2.67 75BMultiple Unit Width
2.67.1 328BbyOsdMultipleUnitWidthSet
API index: 3100
Sets the number of units in horizontal direction.
Input Parameters
Name Type Range Description
Value UWORD32 0x01-0x04 Number of units in horizontal
direction.
Return Values
Name Type Range Description
Status BYTE 0x00-0xFF 0 if successful, error code otherwise
2.67.2 329BbyOsdMultipleUnitWidthGet
API index: 3101
Retrieves the number of units in horizontal direction.
Input Parameters
Name Type Range Description
Option BYTE 0: From cache
1: From SPD
Retrieval method
Return Values
Name Type Range Description
Status BYTE 0x00-0xFF 0 if successful, error code otherwise
Value UWORD32 0x01-0x04 Number of units set in horizontal
direction.
2.67.3 330BbyOsdMultipleUnitWidthSave
API index: 3102
Saves the number from cache into the SPD.
Input Parameters
None
Return Values
Name Type Range Description
Status BYTE 0x00-0xFF 0 if successful, error code otherwise